Goodman GSH130251AC Capacitor Size & Contactor Specs
Factory service specifications for Goodman GSH130251AC Heat Pump Condenser.
The Goodman GSH130251AC 2.0 Ton (24,000 BTU) Heat Pump Condenser uses a 2-pole 30A 24V coil contactor (OEM CONT2P030024VS, universal replacement Packard C230A).
Electrical Component & Replacement Matrix
Verified OEM parts and drop-in universal aftermarket cross-references
| Component | Electrical Spec | OEM Part # | Universal Replacement | Order Online |
|---|---|---|---|---|
| Compressor ContactorRelay Switch | 2-Pole 30A24V Coil | CONT2P030024VS | Packard C230A | Prime Check |
4-Step Goodman GSH130251AC Electrical Replacement Workflow
Always follow OSHA electrical lockout/tagout principles before opening condenser access panels. Capacitors store lethal voltage even with power disconnected.
Locate the outdoor disconnect box mounted on the wall adjacent to your condenser. Pull the handle or remove the pullout block entirely. Switch off the dedicated double-pole AC breaker in your main electrical panel.
Using an insulated screwdriver (holding ONLY the rubberized handle), short the metal shaft between the HERM terminal and COMMON, then between FAN and COMMON to release any residual microfarad charge.
Photograph the wiring first. Transfer wires one-by-one to your replacement capacitor:• HERM (3 prongs): Compressor lead
• FAN (2 prongs): Fan motor lead
• COMMON (4 prongs): Line voltage & contactor lead
Examine the contactor copper points for black carbon pitting or welded contacts. Inspect the plastic housing for dead ants (attracted to 24V magnetic fields). If points are pitted or scored, replace the contactor simultaneously.
Prefer a Certified HVAC Pro on Site Today?
If your compressor is humming without starting, your breaker repeatedly trips, or you are uncomfortable testing high-voltage 240V circuits, connect with an on-call licensed technician in your area.