AllHVACSpecs
Goodman13 SEER3.0 Ton (36,000 BTU)

Goodman GSC130361FB Capacitor Size & Contactor Specs

Factory service specifications for Goodman GSC130361FB Split-System AC Condenser.

Quick Answer • Factory Electrical Specs

The Goodman GSC130361FB 3.0 Ton (36,000 BTU) Split-System AC Condenser uses a 35/5 µF @ 440V round (cylinder) dual-run capacitor (OEM CAP050350440RSP, universal replacement Supco CR35+5X440R).

Capacitor: 35/5 µF @ 440V (Round (Cylinder)) — OEM CAP050350440RSP

Electrical Component & Replacement Matrix

Verified OEM parts and drop-in universal aftermarket cross-references

ComponentElectrical SpecOEM Part #Universal ReplacementOrder Online
Dual-Run CapacitorCompressor + Fan35/5 µF @ 440VRound (Cylinder)CAP050350440RSPSupco CR35+5X440RPrime Check
Universal components meet EIA-456-A HVAC industry manufacturing standards.FTC: Affiliate links support free directory hosting.
Technician Field Protocol • Safety & Installation

4-Step Goodman GSC130361FB Electrical Replacement Workflow

Always follow OSHA electrical lockout/tagout principles before opening condenser access panels. Capacitors store lethal voltage even with power disconnected.

1Kill High-Voltage 240V Supply

Locate the outdoor disconnect box mounted on the wall adjacent to your condenser. Pull the handle or remove the pullout block entirely. Switch off the dedicated double-pole AC breaker in your main electrical panel.

2Discharge Stored Capacitor Voltage

Using an insulated screwdriver (holding ONLY the rubberized handle), short the metal shaft between the HERM terminal and COMMON, then between FAN and COMMON to release any residual microfarad charge.

31-to-1 Terminal Wire Transfer

Photograph the wiring first. Transfer wires one-by-one to your replacement capacitor:HERM (3 prongs): Compressor lead
FAN (2 prongs): Fan motor lead
COMMON (4 prongs): Line voltage & contactor lead

4Inspect Contactor Points & Coil

Examine the contactor copper points for black carbon pitting or welded contacts. Inspect the plastic housing for dead ants (attracted to 24V magnetic fields). If points are pitted or scored, replace the contactor simultaneously.

Emergency 24/7 Local Dispatch

Prefer a Certified HVAC Pro on Site Today?

If your compressor is humming without starting, your breaker repeatedly trips, or you are uncomfortable testing high-voltage 240V circuits, connect with an on-call licensed technician in your area.

Licensed & EPA 608 CertifiedSame-Day Diagnostic TrucksFull System Warranties
Call 24/7: (888) 592-4822Instant connection • No obligation quote
Goodman GSC130361FB Capacitor Size (35/5 µF) & Contactor Specs | AllHVACSpecs.com