Quick Answer • Factory Electrical Specs

The Amana SSZ140601AB 5.0 Ton (60,000 BTU) Heat Pump Condenser uses a 2-pole 30A 24V coil contactor (OEM CONT2P030024VS, universal replacement Packard C230A).

Contactor: 2-Pole 30A (24V Coil) — OEM CONT2P030024VS

Electrical Component & Replacement Matrix

Verified OEM parts and drop-in universal aftermarket cross-references

ComponentElectrical SpecOEM Part #Universal ReplacementOrder Online
Compressor ContactorRelay Switch2-Pole 30A24V CoilCONT2P030024VSPackard C230APrime Check
Universal components meet EIA-456-A HVAC industry manufacturing standards.FTC: Affiliate links support free directory hosting.
Technician Field Protocol • Safety & Installation

4-Step Amana SSZ140601AB Electrical Replacement Workflow

Always follow OSHA electrical lockout/tagout principles before opening condenser access panels. Capacitors store lethal voltage even with power disconnected.

1Kill High-Voltage 240V Supply

Locate the outdoor disconnect box mounted on the wall adjacent to your condenser. Pull the handle or remove the pullout block entirely. Switch off the dedicated double-pole AC breaker in your main electrical panel.

2Discharge Stored Capacitor Voltage

Using an insulated screwdriver (holding ONLY the rubberized handle), short the metal shaft between the HERM terminal and COMMON, then between FAN and COMMON to release any residual microfarad charge.

31-to-1 Terminal Wire Transfer

Photograph the wiring first. Transfer wires one-by-one to your replacement capacitor:HERM (3 prongs): Compressor lead
FAN (2 prongs): Fan motor lead
COMMON (4 prongs): Line voltage & contactor lead

4Inspect Contactor Points & Coil

Examine the contactor copper points for black carbon pitting or welded contacts. Inspect the plastic housing for dead ants (attracted to 24V magnetic fields). If points are pitted or scored, replace the contactor simultaneously.

Emergency 24/7 Local Dispatch

Prefer a Certified HVAC Pro on Site Today?

If your compressor is humming without starting, your breaker repeatedly trips, or you are uncomfortable testing high-voltage 240V circuits, connect with an on-call licensed technician in your area.

Licensed & EPA 608 CertifiedSame-Day Diagnostic TrucksFull System Warranties